• 3d부스이미지-2
  • 3d부스이미지-1
  • 3d부스이미지-2
  • 3d부스이미지-3
  • 3d부스이미지-1
  • 3d부스이미지-2
  • 3d부스이미지-1
  • 3d부스이미지-3
  • 3d부스이미지-1
  • 3d부스이미지-2
  • 3d부스이미지-1
  • 3d부스이미지-2
  • 3d부스이미지-1
  • 3d부스이미지-3
  • 3d부스이미지-1

조회중입니다.

Contract

Contract Opportunity result Lists

Showing 1871 - 1880 of 7209467 results
favorite_border
favorite
DENTAL SERVICE
Notice ID 8dcf6e5e07ca7ad48219d45af35d4a89

This is a Request for Quotation RFQ being issued in addition to a EDIFacnet solicitation These announcements constitute the only solicitation quotations are being requested and a written solicitation will not be issued This acquisition is 100 setaside for small business The Standard Industrial Classification code is 8021 The size standard is 5M This RFQ contains one line item 0001 Service NonPersonal Dental from award through 30 Sep 00 IAW attached Statement of work Quotations will be evaluated in accordance with attached criteria Offers should contain a quotation on hourly basis Offers should contain all supporting documents called for in Statement of Work Place of Performance Holloman AFB NM 88330 OFFERS MUST CONTAIN A COMPLETED COPY OF FAR 522123 OFFER REPRESENTATIONS AND CERTIFICATIONS The Offeror is required to provide their Contractors DUNS Number and Commercial and Government Entity CAGE code with their offer The CAGE code entered must be for that name and address provided by the contractor Offerors are required to be registered in the Central Contractor Registration database CCR Facsimile quotes will be accepted at 5055727333 All responsible sources may submit an offer which will be considered

  • Department/Ind.Agency DEPT OF DEFENSE
  • Subtier DEPT OF THE AIR FORCE
  • Office FA4801 49 CONS PK
  • Notice Type Presolicitation
  • Published Date 2000-03-14 14:00:00+09
favorite_border
favorite
REPAIR/REPLACE HVAC/EMCS CONTROLS IN BLDG 317
Notice ID e1bce2eb6292f369a093a1f7f5a7a0fe

See Attachments

  • Department/Ind.Agency DEPT OF DEFENSE
  • Subtier DEPT OF THE AIR FORCE
  • Office FA4801 49 CONS PK
  • Notice Type Presolicitation
  • Published Date 2000-03-14 14:00:00+09
favorite_border
favorite
ENVIRONMENTAL ADVISORY SERVICES, TFTP-SW-98-8999-B
Notice ID 05f4da4a92ae1f75144db8d2958fd6d3

No Description Provided

  • Department/Ind.Agency GENERAL SERVICES ADMINISTRATION
  • Subtier OFFICE OF ADMINISTRATIVE SERVICES
  • Office OFFICE OF MANAGEMENT SERVICES
  • Notice Type Award Notice
  • Published Date 2000-03-14 14:00:00+09
favorite_border
favorite
47--HOSE, NONMETALLIC. 8 IN.
Notice ID 892289c845bdf4e6e349dc6551a8bd1c

No Description Provided

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Solicitation
  • Published Date 2000-03-14 14:00:00+09
favorite_border
favorite
ENVIRONMENTAL ADVISORY SERVICES, TFTP-SW-98-8999-B
Notice ID 15fd89d9fddffe14d2777fca53d7055f

No Description Provided

  • Department/Ind.Agency GENERAL SERVICES ADMINISTRATION
  • Subtier OFFICE OF ADMINISTRATIVE SERVICES
  • Office OFFICE OF MANAGEMENT SERVICES
  • Notice Type Award Notice
  • Published Date 2000-03-15 14:00:00+09
favorite_border
favorite
PROBES
Notice ID 457af55aac2a330b1afffac84bc9caf6

Presolicitation NoticeDate Submitted 15MAR2000 OCALCPKOAA DIR OF CONTRACTING 7858 5TH ST STE 1 TINKER AIR FORCE BASE OK 731459106 66PROBES SOL F3465000Q0377 DUE 042000 For additional information contact Shirley PippinPkoaa 4057395397 Uniwest Assembly Probes Total of 35 each of various part numbers See website after 20 Mar 00 for copy of solicitation httpwwwepsgov The approximate issueresponse date will be 20 Mar 2000 Electronic procedure will be used for this solicitation See our Web page

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Presolicitation
  • Published Date 2000-03-15 14:00:00+09
favorite_border
favorite
ENVIRONMENTAL ADVISORY SERVICES, TFTP-SW-98-8999-B
Notice ID 142a947275a60d1097b05d960a9ee64a

No Description Provided

  • Department/Ind.Agency GENERAL SERVICES ADMINISTRATION
  • Subtier OFFICE OF ADMINISTRATIVE SERVICES
  • Office OFFICE OF MANAGEMENT SERVICES
  • Notice Type Award Notice
  • Published Date 2000-03-16 14:00:00+09
favorite_border
favorite
CESIUM BEAM TUBE/INSTALLATION
Notice ID da038bc9dd507b786aa55aa1951225e1

This is a Request for Quotation RFQ being issued in addition to an EDIFACNET solicitation These announcements constitute the only solicitation quotations are being requested and a written solicitation will not be issued This acquisition is set aside 100 for small business The Standard Industrial Classification code is 7699 The size standard is 5M This RFQ contains two2 line items 0001 Tube Beam Cesium Datum Inc PN 7504A or equal Must be exact form fit and function replacement QTY two2 ea 0002 Installation of cesium tubes in Datum Inc 4065A FTS Cesuim Time and frequency standard 1025 MHz including disposal of old tube alignment and functional retest of instrument Qty two2 jb All items to be awarded in the aggregate Quotations will be evaluated on the qualifications of the firms to accomplish line item 2 Qoutations must contain summary of qualifications If bidding or equal include product specifications FOB Destination Acceptance destination Shipping from and delivery to Holloman AFB NM Offerors should include a completed copy of FAR 522123 Offeror Representations and Certifications with their quote The Offeror is required to provide their Contractors DUNS Number and Commercial and Government Entity CAGE code with their offer The CAGE code entered must be for that name and address provided by the contractor Offers are required to be registered in the Central Contractor Registration database CCR Facsimile quotes will be accepted at 5055727333 All responsible sources may submit an offer which will be considered

  • Department/Ind.Agency DEPT OF DEFENSE
  • Subtier DEPT OF THE AIR FORCE
  • Office FA4801 49 CONS PK
  • Notice Type Presolicitation
  • Published Date 2000-03-16 14:00:00+09
favorite_border
favorite
SANDBLASTING/PAINTING OF EQUIPMENT
Notice ID c33da861a9ef4168daed9f18b8fc1296

No Description Provided

  • Department/Ind.Agency DEPT OF DEFENSE
  • Subtier DEPT OF THE AIR FORCE
  • Office FA4801 49 CONS PK
  • Notice Type Award Notice
  • Published Date 2000-03-16 14:00:00+09
favorite_border
favorite
UPGRADE PRODUCT RECOVERY FACILITY
Notice ID f78ed2bc4658b35fbddd186aebcca357

This is a combined synopsissolicitation for commercial items prepared in accordance with the format in subpart 126 as supplemented with additional information included in this notice This announcement constitutes the only solicitation proposals are being requested and a written solicitation will not be issued This solicitation No F0260400T0092 is issued as a Request for Quotation RFQ Funds for this acquisition are available This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 9715 This acquisition is 100 setaside for HubZone small business Contract Line ItemsCLIN 0001 SCOPE The project covered by this statement of work consists in furnishing all labor equipment and materials necessary to upgrade the 1000gallon used oil aboveground storage tank AST 887 and the recyclable JP8 AST 888 to meet 40 CFR 1127 overfill protection requirements at the Product Recovery Facility AST 888 is a doublewall steel tank consisting of two 3000gallon separate tanks with a singlewall outer shell Repairs shall include the installation of an highlow level product alarm system design electrical connection from highlow level alarm system to automatically shut off transfer pumps when alarm activates and the installation of visual tank gauges In addition and a permanent eye wash unit shall be connected to existing base utility systems A steel ladder with railing will be installed on the west end of AST 888 USER 56th Civil Engineer Squadron Environmental Programs Flight Compliance Section 56 CESCEVC Telephone 623 8563823 x225 The Environmental Flight POL Program Manager will serve as the AF Project Manager DESCRIPTION The Contractor shall perform the following tasks to complete this statement of work 1 Environmental Compliance Activities The Contractor shall repair the existing overfill alarm system or install a VeederRoot VR overfill alarm system or equal on AST nos 887 and 888 see Attachment 1 VeederRoot Specifications are 11 VR Guardian AST Monitoring System Item 848590110 1 unit 12 VR Guardian HighLow Level Sensor Item 794390Yxx 3 sensors 13 The Contractor shall mount the AST Monitoring System Console in a fanventilated metal box to prevent overheating during summer months An example of an acceptable system is located at building 1018 14 The Contractor shall test the system to ensure it is accurate and operational for all three ASTs 15 The Contractor shall wire the overfill alarm to the transfer pumps so that the pumps will automatically stop when the overfill alarm activates 2 Install Visual Tank Volume Gauges The Contractor shall install one Hersey Hydraulic Visual Gauge or equal liquid volume in gallons on each of the three 3 ASTs 3 Install Permanent Eyewash Unit The Contractor shall install a permanent eyewash unit equal to construction and design to American Health Safety Item 2133021 Model W9332 wfoot pedal See Attachment 2 31 The Contractor shall connect the permanent eyewash unit to the bases water supply system 4 Construction Activities LadderPlatform at AST 888 The Contractor shall install steel ladder to hatchway at the west end of AST 888 and on the north side of the tank Ladder shall be constructed of steel grating with dimensions of 25 to 30 feet in width and approximately 8 feet in height similar to the existing ladderplatform on the south endwest side of AST 888 41 Ladder will be welded securely to tank andor external framework 42 Ladder shall be painted to match ASTs in color and type 5 Piping Supports The Contractor shall install metal piping supports on AST nos 887 and 888 Two supports per pipe for a total of eight 8 supports The Contractor shall seal the drilled holes in the concrete pad with JP8 resistant silicone sealant 6 SCHEDULE AND SUBMITTALS The Contractor shall develop a schedule which incorporates all critical work elements and submittals described in the Statement of Work Estimated time to complete this SOW is 6 months from receipt of the Notice to Proceed 7 ITEMS AND DATA TO BE FURNISHED BY THE GOVERNMENT The AF Project Manager or his designee will coordinate site access and site layout to include any equipment storage requirements All required utilities clearances through 56 CES AF Form 103s shall be obtained by CEVC 8 DEVIATION FROM SCOPE OF WORK The Contractor shall not depart from nor perform work outside of this Statement of Work and criteria on which the Statement of Work is based without the written direction of the Contracting Officer CO If the contractor performs such work without written approval it does so at its own risk Any changes to this SOW will be coordinated with 56 CESCEVC as well as the CO 9 ACCEPTANCE OF WORK The AF Project Manager will approve and accept all work and submittals 10 VISIT TO SITE PRIVATE SOURCES AND GOVERNMENTAL AGENCIES The Contractor shall advise the AF Project Manager of each proposed visit to the site private sources and government agencies federal state county and city prior to each visit 11 OTHER REQUIREMENTS The Contractor shall be a licensed contractor registered with the State of Arizona Registry of Contractors 12 The Contractor shall not enter into any subcontracts that are not identified in its original proposal without prior written approval of the CO 13 An Manufacturer DistributorAuthorized Service Provider must install overfill protection alarm and monitoring equipment and submit to the Manufacturer and 56 CESCEVC the manufacturers warranty documentation for equipment installed 14 RELEASE OF DATA All data reports and materials relative to this SOW are the property of the Government and will not be released by the Contractor without written approval of the CO 15 RESPONSIBILITY FOR FIELD WORK The Contractor shall be responsible for all damages to persons and property that occur as a result of the Contractors fault or negligence in connection with field work and shall save and hold the Government free from all claims and suits arising from such damage This is a brand name or equal requirement the FAR Clause 522116 applies Basis of award award will be made to the lowestprice Offeror best demonstrating their ability to satisfy the technical capabilities of the items specified Offerors of any equal must provide descriptive literature to this office for evaluation Required delivery 30 days ARO FOB Destination to Luke AFB AZ All prices shall include all Federal State and Local taxes The following FAR DFARS provisions and clauses applies to this solicitation FAR 522121 Instructions to OfferorsCommercial Items Far 522124 Contract Terms and Conditions commercial Items FAR 522125 Contract Terms and Conditions Required to Implement Statutes or Executive OrderCommercial Items with addenda incorporating FAR clauses 5222226 Equal Opportunity 5222235 Affirmative Action for Special Disabled and Vietnam ERA Veterans 5222236 Affirmative Action for Workers with Disabilities 5222241 DFARS 2522127001 Contract terms and Conditions Required to Implement Statutes or executive orders Applicable to Defense Acquisitions of Commercial Items with addenda incorporating DFARS clausess 2522257001 Buy American Act and Balance of Payment Program DFARS 2522047004 Required Central Contractor Registration MAR 1998 DFARS 2047304 Offers shall be submitted in writing and received not later than 430 PM local time 29 Mar 00 Arizona does not observe daylight savings time Direct any questions or concerns to TSgt Ken Miller at 623 8567179 X 255 All proposals must be faxed to 623 8563438 or email kenmillerlukeafmil ATTACHMENT 1 VeederRoot Company Guardian AST Monitoring System Product Description The Guardian AST Monitoring System Form NO 848590110 is designed for compliance and inventory control aboveground storage tanks where intank leak detection is not required The system is capable of monitoring one or two tanks FEATURES The guardian has the following features A twoline 24characterperline display A cursor keypad and a keypad for stepping through menudriven programming and operation functions A red warning indicator on the front panel to alert you of leaks and other warning and alarm conditions An internal audible warning and alarm indicator to alert you of leaks and other warning and alarm conditions The following probe and sensor is compatible with the Guardian AST Monitoring System 794390YXX HighLow Level Sensor HighLow Level Sensors indicate delivery and overfill conditions Will fax picture upon request ATTACHMENT 2 Emergency Eyewash Unit Product Description Deluxe Full BodyEye Wash Emergency Station Eyewash station has two gentle spray outlet heads with a yellow ABS plastic bowl Drench Shower features stay open ball valve with pull rod and a yellow ABS plastic shower head Furnished with galvanized intermediate pipe and fittings with 9 floor flange 114 inlet and outlet

  • Department/Ind.Agency DEPT OF DEFENSE
  • Subtier DEPT OF THE AIR FORCE
  • Office FA4887 56 CONS CC
  • Notice Type Presolicitation
  • Published Date 2000-03-17 14:00:00+09