Notice ID
6b39a061047cc188a34f1298338b5431
This is a Request for Quotation RFQ being issues in addition to an EDI FACNET solicitation Proposals are being requested and a written solicitation will not be issued This acquisition is 100 set aside for small business The Standard Industrial Classification code is 5599 The size standard is 5000000 in annual receipts This RFQ contains two2 line items 0001 Trailer Custom 5ea Construction 2inx6in steel tube and bumper 2 in x 2 in steel tube crossmembers on appx 18in centers 18 gauge steel deck with 12 gauge tenders 70 in wide x 145 in long bed size with two 2 6000 lb axles equiped with leaf springs sliders Hitch 2 ball couplers Lights Per ICC with license plate and bracket Fuel tank belly mounted 160 gal 2 in fill mechanical gauge pickup return ports spare port drain and 2 in vent port 18 in high Tires IT23585R16 load range E One front jack stand with shoe two 2 rear stabilizer stands 6 pole plug and safety chans Paint metal prep prime two2 coats and two2 coats of black acrylic enamel paint 0002 Trailer Custom 3ea Construction 2in x 6 in steel tube frame and bumper 2 in x 2 in steel tube crossmembers on 18 in centers 18 gauge steel deck with 12 gauge tenders 70 in x 145 in long bed with one 7000 lb axle All axles are to be equiped with leaf springs and sliders Hitch 2 in ball coupler Lights Per ICC with licence plate light and bracket Fuel Tank Belly mounted 110 gal with 2 fill mechanical gauge pickup and return port spare port drain 2 in vent port 18 in high Tires 12165 load range F One front jack stand with shoe two2 rear stabilizer stands six6 pole plug and safety chains Paint metal prep two 2 coats of primer and two 2 coats of acrylic enamel paint Award will be made to lowest price technically acceptable offer Specifications in addition to above should be provided with qoute Questions about technical requirements may be directed to Mr Doucet at 5054757268 FOB destination Acceptance destination Deliver to Holloman AFB NM The attached FAR and DFARS clauses apply to this acquisition OFFEROR SHALL PROVIDE A COMPLETED COPY OF FAR 522123 WITH THEIR QUOTE Offeror is required to provide their Contractors DUNS number and Commercial and Government Entity CAGE code with their offer The CAGE code must be for that name and address provided by the Contractor Offerors are required to be registered in the Central Contractor Registration database CCR to be considered Quotes may be faxed to 5054757333 All responsible sources may submit an offer which will be considered
-
Department/Ind.Agency
DEPT OF DEFENSE
-
Subtier
DEPT OF THE AIR FORCE
-
Office
FA4801 49 CONS PK