J -- OVERHAUL OF GLOBE TURBOCHARGERS
Notice ID 65a630da1a4aa80eea6f460de91c1345

No Description Provided

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Award Notice
  • Published Date 2001-12-19 14:00:00+09
favorite_border
favorite
36 -- Contractor to provide 102 each 24 VOLT DC PANELBOARDS AND 102 EACH 120 VOLT AC PANEL BOARDS FOR 41' UTILITY BOATS24
Notice ID 2234cb74ef2f145f46529ab315820f0e

17 This synopsis is to respond to questions of offerors on the above Solicitation QUESTION 1 Trimcribbage piece Is that a single piece or in 4 pieces ANSWER The trimcribbage peice is a single piece QUESTION 2 DIN rail mounted pieces Would that be all including the Main Circuit breaker or only the branch breakers ANSWER All the pieces including the Main Circuit Breaker branch cicrcuit beakers and terminal stripes shall be DIN rail mounted QUESTION 3 On the 120 volt AC panel You call out a transformer circuit Beaker Do you have a suggested list of Manufactuers ANSWER No This circuit breaker has no unique features It is a typical branch circuit breaker which shall meet the requirements of the solicitation Refer any questions to Sandy Miller at 410 7626452

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Modification/Amendment/Cancel
  • Published Date 2001-12-19 14:00:00+09
favorite_border
favorite
36 -- Contractor to provide 102 each 24 VOLT DC PANELBOARDS AND 102 EACH 120 VOLT AC PANEL BOARDS FOR 41' UTILITY BOATS24
Notice ID 95f987a8d7f0c1fa11a72a691a3351c3

17 This synopsis is to respond to questions of offerors on the above Solicitation QUESTION 1 Trimcribbage piece Is that a single piece or in 4 pieces ANSWER The trimcribbage peice is a single piece QUESTION 2 DIN rail mounted pieces Would that be all including the Main Circuit breaker or only the branch breakers ANSWER All the pieces including the Main Circuit Breaker branch cicrcuit beakers and terminal stripes shall be DIN rail mounted QUESTION 3 On the 120 volt AC panel You call out a transformer circuit Beaker Do you have a suggested list of Manufactuers ANSWER No This circuit breaker has no unique features It is a typical branch circuit breaker which shall meet the requirements of the solicitation Refer any questions to Sandy Miller at 410 7626452

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Modification/Amendment/Cancel
  • Published Date 2001-12-19 14:00:00+09
favorite_border
favorite
J -- DRYDOCK AND REPAIRS USCGC CHIPPEWA (WLR-75404)
Notice ID 5f3347bd1c090108a4ec55546a1ca640

The United States Coast Guard Maintenance Logistics Command Atlantic intends to issue a commercial Request for Quotes RFQ for drydock and repair of the USCGC CHIPPEWA WLR75404 a 75 foot tender and her 130 foot barge The Coast Guard intends to conduct this procurement in accordance with Federal Acquisition Regulation FAR part 12 Acquisition of Commercial Items and FAR Subpart 135 Test Program for Certain Commercial Items The simplified acquisition will be issued as a best value Request for Quotes RFQ on or about 18 January 02 with quotes due on or about 19 February 02 The RFQ will be issued via the Federal Business Opportunities FEDBIZOPPS web page at wwwepsgov Hard copies of the specification and solicitation will not be issued A CDROM containing all applicable drawings will be sent via US mail if requested Send all requests via email to bhancockmlcauscgmil It is incumbent upon contractors to monitor the FEDBIZOPPS web page for RFQ release and all subsequent amendments FEDBIZOPPS also contains an optional automatic notification service The standard industrial classification code is 3731 and the NAICS is 336611 This acquisition will be solicited unrestricted The home pier of the vessel is OWENSBORO KENTUCKY All work will be performed at the contractors facility The performance period will be 54 days with a start date on or about 29 APR 02 The scope of the acquisition is for the drydocking overhauling cleaning and repairing of various items aboard the USCGC CHIPPEWA WLR75404 Provide all labor material and equipment necessary to perform drydock repairs including but not limited to the following clean and inspect fuel tanks remove and dispose of fuel up to 5000 gallons remove inspect and reinstall propeller shafts renew propellers clean and test grid coolers overhaul and renew valves inspect and test air receivers and relief valves remove inspect and reinstall rudder assemblies for steering and flanking systems preserve spud and spud well on tender and barge overhaul air capstan overhaul Appleton KB2010 Crane inspect various deck fittings preserve sewage and grey water collection and holding tank preserve barge buoy deck preserve underwater body renew draft figures barge and tender preserve freeboard provide temporary messing and berthing provide temporary logistics routine drydocking of tender and barge modify barge side shell plating install new tenderbarge interface system renew deck covering system overhaul steering and flanking rudders hydraulic cylinders GFP report in accordance with solicitation Section H Option items include but are not limited to the following remove inspect and reinstall intermediate shafts renew waterlubricated shaft bearings renew shaft sleeves renew tender towing knees Trained welders who have been certified by the applicable regulatory code performance qualification procedures shall accomplish all welding and brazing The following Geographic Restriction applies to tender and barge Restricted to the Western Rivers of the United States The Western Rivers means the navigable portions of the Mississippi River and its tributaries above mile 0 of the Lower Mississippi River Navigable tributaries of the Mississippi River include only the waterways within the areas of jurisdiction of Coast Guard Aids to Navigation Facilities as described in Light List Volume V COMDTINST M165025 and the Tennessee Tombigbee Waterways to the mouth of the Mobile River This includes protected portions of the Intra Coastal Waterway connected to the Western Rivers but specifically excludes unprotected or open waters such as Mobile Bay Lake Borne or the Gulf of Mexico This includes protected portions of the Intra Coastal Waterway connected to the Western Rivers but specifically excludes unprotected or open waters such as Mobile Bay Lake Borne or the Gulf of Mexico ATTENTION Minority Womenowned and Disadvantag

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Presolicitation
  • Published Date 2001-12-19 14:00:00+09
favorite_border
favorite
20 -- METRIC TURNBUCKLES
Notice ID 0ffcdb0890bce4562a7251c34ee4865a

This is a combined synopsissolicitation for commercial items prepared in accordance with the format in FAR Subpart 126 as supplemented with additional information included in this notice and FAR Part 13 Simplified Acquisition Procedures A written solicitation will not be issued This announcement is the solicitation and quotations are being requested The solicitation is issued as a request for quote RFQ The RFQ number is DTCG8002Q3FA629 The RFQ incorporates provisions and clauses that are in effect through Federal Acquisition Circular 9727 This is 100 small business set aside procurement The associated North American Industry Classification System NAICS Code is 332722 and the size standard is 500 employees Requirement is for marine closed body metric turnbuckles for the US Coast Guard Cutter EAGLE Turnbuckle sizes and quantities are as follows CLIN 0001 30 each metric turnbuckles with jaw end fittings on both ends nominal size 8 thread size M45 CLIN 0002 6 each metric turnbuckles with jaw end fittings on both ends nominal size 6 thread size M36 CLIN 0003 3 each Metric turnbuckles with jaw end fittings on both ends nominal size 4 thread size M33 CLIN 0004 10 each Metric turnbuckles with jaw end fittings on both ends nominal size 3 thread size M30 CLIN 0005 5 each Metric turnbuckles with jaw end fittings on both ends nominal size 2 thread size M24 Turnbuckle bodies shall be galvanized and manufactured in accordance with DIN 82004 and end fittings shall be manufactured in accordance with DIN 82008 Turnbuckles shall be proof tested to twice the safe working load Delivery will be FOB destination to Coast Guard Yard Baltimore Maryland within 6 weeks after purchase order award date Acceptance of the units will be at destination The contractor shall extend to the government the full coverage of commercial sale warranty provided such warranty is available at no additional cost to the government This will be a FirmFixed Price purchase order Quotes shall address all requirements in this combined synopsissolicitation and shall provide clear evidence of understanding and the ability and willingness to comply with the Governments requirement Failure to address a specificationrequirement will be construed by the Government as inability to meet the need or the offerors taking exception to it The Government anticipates awarding one purchase order resulting from this combined synopsissolicitation to the responsible offeror whose offer conforming to this synopsissolicitation will offer the best value to the Government price and other factors considered Quotations will be evaluated in accordance with Federal Acquisition Regulation FARSubpart 131062Evaluation of quotations or offers Award will be made based on vendors A Technical Capability of the item offered to meet the Government requirements B Past Performance C Delivery Schedule and D Price The Government reserves the right to award a purchase order without discussions All interested responsible small business firms should submit their quotation no later than January 2 1200 pm EDT to US Coast Guard MLCLANT vpl4 300 E Main Street Norfolk VA 235109102 ATTN Sandy Stevens Facsimile copies will be accepted at 7576284676 All vendors are to include with their quotes a completed copy of Provision 522123 Offeror Representations and CertificationsCommercial Items which may be downloaded from httpwwwarnetgov The following Federal Acquisition Regulation FAR terms and conditions apply to this RFQ Provision at 522121 Instructions to OfferorsCommercial Paragraph f Deleted the Clause at 522124 Contract Terms and ConditionsCommercial Items the Clause at 522125 Contract Terms and Conditions Required to Implement Statutes or Executive OrdersCommercial Items including subparagraphs 115222221 Prohibition of Segregated Facilities 12 522

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Presolicitation
  • Published Date 2001-12-19 14:00:00+09
favorite_border
favorite
Z -- REPAIRS TO AMERICAN SHOALS LIGHT
Notice ID bd11f2c55431751d800b9661ab6e380d

NOTE THIS SOLICATION NUMBER SHOULD BE DTCG8202B3WCA21 SO ALL CORRESPONDENCE SHOULD REFERENCE THAT NUMBER

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Modification/Amendment/Cancel
  • Published Date 2001-12-19 14:00:00+09
favorite_border
favorite
Z -- REPAIRS TO AMERICAN SHOALS LIGHT
Notice ID 9dba2d08ebb856baf12f9cc0c6ee7a5e

SOURCES SOUGHT Contractor to furnish all necessary labor materials and equipment to complete repairs to the American Shoals Light a historic offshore structure located approximately six 6 miles offshore on Sugarloaf Key Monroe County Florida Work includes but is not limited to all labor equipment materials and tools necessary to complete the following work repairing and painting the exterior surfaces of this 110 foot tall skeleton structure Structural repairs include the replacement of clamps on the connection nodes at the first level above the water line installation of reinforced concrete pile jackets and renewal of cathodic protection anodes Other work items include the selective refurbishment and painting of interior and exterior items and the replacement of the lantern room windows The applicable North American Industry Class System NAICS Code is 235910 The small business size standard is a threeyear averaged annual gross receipt of 115 million Estimated construction price range is 50000000 to 100000000 Bid payment and performance bonds are required Performance period is 180 calendar days There is no charge for the solicitation package All bid requests must be submitted in writing and may be faxed to 3052786696 No telephone requests shall be accepted All responsible sources may submit a bid which will be considered by this agency This action is being considered for 100 percent setaside for HUBZone small business concerns Interested HUBZone small business concerns should indicate their interest to the Contracting Officer in writing as early as possible but to be received not later than 15 calendar days of this notice As a minimum the following information is required a a copy of the certificate issued by the SBA of your qualifications as a HUBZone concern b a positive statement of your intention to submit an offer for this solicitation as a prime contractor c evidence of experience in work similar in type and scope to include contract numbers project titles dollar amounts and points of contacts and telephone numbers and d provide evidence of bonding capability to the maximum magnitude of the project to include both single and aggregate totals All information must be submitted in sufficient detail for a decision to be made on availability of interested HUBZone concerns Failure to submit all information requested will result in a contractor not being considered as an interested HUBZone concern If adequate interest is not received from HUBZone concerns by close of business 15 calendar days from the date of this notice this solicitation will be issued on an unrestricted basis without further notice Therefore replies are requested from large and small business concerns as well as from HUBZone concerns ATTENTION Minority Womenowned and Disadvantaged Business Enterprises The Department of Transportation DOT Office of Small Disadvantaged Business Utilization OSBDU has a program to assist minority womenowned and disadvantaged business enterprises to acquire shortterm working capital and bonding assistance for transportationrelated contracts This is applicable to any eligible prime or subcontract at any tier The DOT Bonding Assistance Program enables firms to apply for bid performance and payment bonds up to 10 million per contract The DOT provides an 80 guarantee on the bond amount to a surety against losses Loans are also available under the DOT ShortTerm Lending Program STLP at prime interest rates to provide accounts receivable financing The maximum line of credit is 50000000 For further information and applicable forms concerning the Bonding Assistance Program andor the STLP please call the OSDBU at 800 5321169

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Sources Sought
  • Published Date 2001-12-19 14:00:00+09
favorite_border
favorite
Z -- REPAIR/FINISH/RESEAL BUILD EXTERIORS & REROOF PAINT STORAGE & FUEL PUM BUILDINGS AT STATION TILLAMOOK BAY, GARIBALDI, OR
Notice ID 386e25f0114ec9a456681edbb727e329

No Description Provided

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Award Notice
  • Published Date 2001-12-19 14:00:00+09
favorite_border
favorite
99 -- FABRICATE 1500 LB CONCRETE SINKERS
Notice ID ffe5d0907ed9a84fce45c87896a29e47

Fabricate 300 1500 lb tapered concrete sinkers according to specifications and drawings to USCG ANT Colfax The USCG ANT Colfax has 25 tapered forms available for use and may be poured on site References American Society for Testing and Materials ASTM A36A36M Standard Specification for Carbon Structural Steel C15096 Specification for Portland Cement C3393 Spec for Concrete Aggregates C14390A Test Method for Slump of Hydraulic Cement Concrete C3996 Test Method for Compressive Strength of Cylindrical Concrete Speciments American Concrete Institute ACI ACI 318 Building Code Requirements for Reinforced Concrete Applicable Drawing USCG CEU DWG 62192D Standard Sinker 8th District oan Sheet 3 of 4 Requirements Releasing agents USE only environmentally safe releasing agents when pouring sinkers Contractor shall not pour directly on asphalt or concrete Tarpaulins or plastic sheeting must be provided to cover all asphalt and concrete during on site pours All pours shall be made between the hours of 0730 to 1530 Customer shall be notified at least 72 hours in advance of delivery or start of work Delivery of all sinkers must be made by March 1 2002 Contractor shall furnish all labor materials transportation and equipment to fabricate and deliver 225 1500lb sinkers to the USCG ANT Colfax co Army Corps of Engineers Lock and Dam 3 Rt 3 Colfax LA 71417 No deliveries are to be made on Saturdays Sundays or Federal Holidays Cured sinkers shall be within 3 or 10 of the design weight The contractor shall replace any sinker found to be out of tolerance weight at no additional cost to the Government A readymix concrete must be used and meet the following requirements The mix shall be designed to provide a minimum compressive strength of 3000 psi at 28 days Tests shall be made at the discretion of the Contracting Officer Cured concrete shall weigh no less than 140 pounds per bulk cubic foot of sinker Portland cement shall be in accordance with ASTM C 15 Type I or II Fine aggregate sand shall be in accordance with ASTM C 33 Course aggregate shall be Class 4M size No 7 graded from 12 inch to No 4 sieves or sizes No 67 graded from 34 inch to No 4 sieves in accordance with ASTM C 33 The slump of the concrete shall be at least 2 inches and will not exceed 5 inches as delivered The slump test shall be in accordance with ASTM C 143 Samples for slump determination will be taken from concrete during placing in the forms Slump test may be conducted at the Contracting Officers discretion Compressive Tests as required of specimens shall be in accordance with ASTM C 39 Tests will be made at 7B and 28 days from time of molding Six specimens will be broken from each batch of concrete tested 3 at 7 days and 3 at 28 days and their average strength represents the strength of the batch Compressive test may be conducted at the Contracting Officers discretion All workmanship placement and curing shall be in accordance with the applicable sections of ACI 318 Concrete shall be uniformly distributed within the forms by the use of vibrators or other means Finished concrete shall be free of voids planes or discontinuity or areas of honeycomb All concrete sinkers shall be allowed to cure for a minimum of three days before they are moved or stacked Contractor shall supply oneinch 1 diameter round stock steel which shall be placed in the concrete and used to life the sinker The steel shall meet the requirements of ASTM A36 Additionally the lifting eyes shall be shaped and positioned as shown on the applicable drawings Past sinker price was 350 at 4395 a piece Request for quotations are available by contacting MS Eva Johnson 3145393900 x356 or Jane Indihar at x372

  • Department/Ind.Agency
  • Subtier
  • Office
  • Notice Type Modification/Amendment/Cancel
  • Published Date 2001-12-19 14:00:00+09
favorite_border
favorite
C--INDEFINITE DELIVERY CONTRACT FOR ARCHITECT/ENGINEER DESIGN SERVICES
Notice ID 3e82a59b8f355ac184eb72220110748e

NA SUBMISSION REQUIREMENTS See Note 24 for general submission requirements Interested firms having the capabilities to perform this work must submit two copies of SF 255 1192 editionfor the prime firm and all consultants to the above address not later than the close of business on the 30th day after the date of this announcement If the 305h day is a Saturday Sunday or Federal holiday the deadline is the close of business of the next business day Include the firms ACASS number in SF 255 Block 3b For ACASS information call 503 8084594 In SF 255 Block 10 describe owned or leased equipment that will be used to perform this contract as well as CADD capabilities Firms must also submit a list of all significatn equipment and softwar includ ing email and ftp capabilities intended to be used on this contract All firms responding that do not have a current within the past 12 months SF 254 on file with this office must also furnish a completed current SF 254 Provide submittals in the o rder presented in the selection criteria All submittals shall be prepared to be compatible with MS Windows formatted to less then 100 pages not including CADD samples and submitted electronically on a compact disc CD with three hardcopies Solicita tion packages are not available This is not a request for proposal

  • Department/Ind.Agency DEPT OF DEFENSE
  • Subtier DEPT OF THE ARMY
  • Office W072 ENDIST HUNTINGTON
  • Notice Type Presolicitation