Notice ID
c6c41788ceeb40fead3e6491ad2e7f32
Update 41224 Additional Questions Provide Site Photos Extend Solicitation Deadline to close Thursday 18 April Remaining questions will be posted on Monday This solicitation has been updated to provide site photos provide the answers to a few of the questions received and extend the solicitation deadline to Thursday 18 April There were a few additional questions recieved Those questions and responses will be posted on Monday 15 April Questions and Answers 1 SAMgov lists the Solicitation No as FA286024Q4007 however the Combined SynopsisSolicitation documents lists FA 268024Q4007 Would the Government please confirm the correct solicitation number for this effort Government Response The correct number is FA286024Q4007 2 Please verify if the backup electric heaters for the 2 5ton Trane units are staying or being replaced Per the SOW No additional electric heat is required for the replacement equipment however the heaters are older and need to confirm the intent is to reuse the existing units Government response The intent is to reuse the existing units 3 The indoor Liebert units are on platforms if the new units are the exact same size please confirm reuse of the existing platforms is acceptable or are they to be replaced with new Please note that if you want new platforms that will change this requirement and may change this from a service to construction It would extend procurement time and make the estimated value more expensive I would have to look into how this would change the requirement Government Response The Existing platforms will be fine if the size of the unit matches the platforms Questions and Answers Updated 4824 This list will be updated as additional questions are submitted 1 Need to make sure we are doing split systems with condensers what voltage Government Response208 2 Upflow or DownflowGovernment Response Upflow 3 If downflow what is the finished floor height for stand Government Response NA 4 Do they need options reheat and humidity Government Response We do not need these options Update 4824 The Combined Synopsis and Solicitation Attachment was updated to correct an inconsistency in the response deadline The response deadline for this solicitation is 41624 This requirement is to replace two CRAC units 6 tons each two heat pumps 5 tons each and associated line sets If replacement CRAC condensers do not have an integrated disconnect this will have to be added to the project No additional electric heat is required for the replacement equipment There is a brand name requirement for the use of specific Trane and Liebert brand parts included in the SOW All work must be completed IAW the SOW Attachment 1 Note This requirement is 100 setaside for small disadvantaged businesses A site visit is scheduled for 0930 on Thursday April 11 2024 Additional information and instructions are included in the attached Combo Synopsis and Solicitation Please see the attached Combo Synopsis and Solicitation and follow the Instructions to Offerors to provide an offer Email offers to the primary and secondary points of contact by the response deadline
-
Department/Ind.Agency
DEPT OF DEFENSE
-
Subtier
DEPT OF THE AIR FORCE
-
Office
FA2860 316 CONS PK